Proactive offers a range of 12V sampling and purging pumps in plastic and stainless steel, and peristaltic pumps for various environmental applications.
-
12V Sampling Pump Mega-Monsoon 61m
- Pumping depth: 61 m DTW
- Watt consumption (max): 600 W (max)
- DC volt recommendation: 12-15 VDC
- Amp consumption (max): 40 A
- Dimensions: Length: 26″ / Diameter: 1.82″
- Required tubing: 10 mm ID
- Supplied with: 64 m cable, quick disconnect plug
- Required: Power Booster 3 Controller
719.00 € excl. VAT12V Sampling Pump Mega-Monsoon 61m
719.00 € excl. VAT -
12V Sampling Pump Monsoon 37m
- Pumping depth: 37 m DTW
- Watt consumption (max): 450 W (max)
- DC volt recommendation: 12-15 VDC
- Amp consumption (max): 30 A
- Dimensions: Length: 20″ / Diameter: 1.82″
- Required tubing: 10 mm ID
- Supplied with: 39 m cable, quick disconnect plug
- Required: Power Booster 2 Controller
519.00 € excl. VAT12V Sampling Pump Monsoon 37m
519.00 € excl. VAT -
Low Flow Sampling Controller
Standard Engineered Plastic line, including the Cyclone®, Mini-Typhoon®, Typhoon®, Twister®, Mini-Monsoon, Super Twister®, Tornado®, and Abyss® pumps, is compatible with this controller, which was designed to work in tandem with mentioned devices.
449.00 € excl. VATLow Flow Sampling Controller
449.00 € excl. VAT -
12V Peristaltic Pump Athena
- Pumps up to 2.5 liters per minute or as low as 40 mL per minute
- Suction lift up to 8 m
- Supplied with one pump head
- 3 m of DC battery clamps to hook up for super long sampling events
- Dimensions: Depth 25 cm x Width 33 cm x Height 17 cm
- Weight of Product: 3.6 kg
1,319.00 € excl. VAT12V Peristaltic Pump Athena
1,319.00 € excl. VAT -
3″ ATEX VP3 Top Loader Low Draw Down
- Pump length: 830 mm
- Liquid inlet position: Top
- Max flow rate: >870 l/hr
- Pump discharge cycle: 0.5 litres
- Pump outside Diameter: 70 mm
- Min operating borehole diameter: 80 mm
- Max working depth: 130 m
- Pump weight: 3.5 kg
Price On Request3″ ATEX VP3 Top Loader Low Draw Down
Price On Request -
3″ ATEX VP3 Bottom Loader Low Draw Down
- Pump length: 670 mm
- Liquid inlet position: Bottom
- Max flow rate: >900 l/hr
- Pump discharge cycle: 0.5 litres
- Pump outside Diameter: 70 mm
- Min operating borehole diameter: 80 mm
- Max working depth: 130 m
- Pump weight: 3 kg
Price On Request3″ ATEX VP3 Bottom Loader Low Draw Down
Price On Request -
4″ ATEX VP4 Top Loader Low Draw Down
- Pump length: 750 mm
- Liquid inlet position: Top
- Max flow rate: >1200 l/hr
- Pump discharge cycle: 0.4 litres
- Pump outside Diameter: 90 mm
- Min operating borehole diameter: 100 mm
- Max working depth: 130 m
- Pump weight: 6 kg
Price On Request4″ ATEX VP4 Top Loader Low Draw Down
Price On Request -
4″ ATEX VP4 Bottom Loader Low Draw Down
- Pump length: 580 mm
- Liquid inlet position: Bottom
- Max flow rate: >1200 l/hr
- Pump discharge cycle: 0.5 litres
- Pump outside Diameter: 90 mm
- Min operating borehole diameter: 100 mm
- Max working depth: 130 m
- Pump weight: 5.5kg
Price On Request4″ ATEX VP4 Bottom Loader Low Draw Down
Price On Request -
2″ ATEX VP2 Top Loading Pump
- Pump length: 995 mm
- Liquid inlet position: Top
- Max flow rate: >400 l/hr
- Pump discharge cycle: 0.3 liters
- Pump outside Diameter: 44 mm
- Min operating borehole diameter: 50 mm
- Max working depth: 130 m
- Pump weight: 2 kg
Price On Request2″ ATEX VP2 Top Loading Pump
Price On Request -
3″ ATEX VP3 Top Loading Pump
- Pump length: 1190 mm
- Liquid inlet position: Top
- Max flow rate: >1000 l/hr
- Pump discharge cycle: 0.6 litres
- Pump outside Diameter: 70 mm
- Min operating borehole diameter: 80 mm
- Max working depth: 130 m
- Pump weight: 5.5 kg
Price On Request3″ ATEX VP3 Top Loading Pump
Price On Request -
4″ ATEX VP4 Top Loading Pump
- Pump length: 1100 mm
- Liquid inlet position: Top
- Max flow rate: >2100 l/hr
- Pump discharge cycle: 0.9 – 1.1 litres
- Pump outside Diameter: 90 mm
- Min operating borehole diameter: 100 mm
- Max working depth: 130 m
- Pump weight: 7.5 kg
Price On Request4″ ATEX VP4 Top Loading Pump
Price On Request -
2″ ATEX VP2 Bottom Loading Pump
- Pump length: 945 mm
- Liquid inlet position: Bottom
- Max flow rate: >475 l/hr
- Pump discharge cycle: 0.33 litres
- Pump outside Diameter: 44 mm
- Min operating borehole diameter: 50 mm
- Max working depth: 130 m
- Pump weight: 1.5 kg
Price On Request2″ ATEX VP2 Bottom Loading Pump
Price On Request -
3″ ATEX VP3 Bottom Loading Pump
- Pump length: 1120 mm
- Liquid inlet position: Bottom
- Max flow rate: >1200 l/hr
- Pump discharge cycle: 0.6 litres
- Pump outside Diameter: 70 mm
- Min operating borehole diameter: 80 mm
- Max working depth: 130 m
- Pump weight: 5 kg
Price On Request3″ ATEX VP3 Bottom Loading Pump
Price On Request -
4″ ATEX VP4 Bottom Loading Pump
- Pump length: 1005 mm
- Liquid inlet position: Bottom
- Max flow rate: >2880 l/hr
- Pump discharge cycle: 0.9 – 1.1 litres
- Pump outside Diameter: 90 mm
- Min operating borehole diameter: 100 mm
- Max working depth: 130 m
- Pump weight: 7.5kg
Price On Request4″ ATEX VP4 Bottom Loading Pump
Price On Request -
4″ ATEX Pump ID BETA EX 13 kW 2.2
Pumping of liquids and extraction of leachate in landfill, drainage of fluids contaminated by hydrocarbons and groundwater. The ATEX pumps in conformity with 2014/34/UE Directive can be installed in potentially explosive atmospheres according to the marking explained hereafter.
Price On Request4″ ATEX Pump ID BETA EX 13 kW 2.2
Price On Request